Extracorporeal: VAD DevelopmentBench Tubing Studies31 Matching Records
Laumen M, Kaufmann T, Timms D, Schlanstein
P, Jansen S, Gregory S, Wong KC,
Schmitz-Rode T, Steinseifer U.
Department of Cardiovascular
Engineering, Institute of Applied
Medical Engineering, Helmholtz
Institute, RWTH Aachen University,
Aachen, German, "Flow analysis of ventricular assist
device inflow and outflow cannula
positioning using a naturally shaped
ventricle and aortic branch.", Artif Organs. 2010 Oct;34(10):798-806. doi: 10.1111/j.1525-1594.2010.01098.x.
|
8024A
|
Dur O, Lara M, Arnold D, Vandenberghe S,
Keller BB, DeGroff C, Pekkan K.
Biomedical Engineering Department,
Carnegie Mellon University,
Pittsburgh, PA 15219, USA., "Pulsatile in vitro simulation of the
pediatric univentricular circulation
for evaluation of cardiopulmonary
assist scenarios.", Artif Organs. 2009 Nov;33(11):967-76.
|
8008A
|
Frazier OH., Department of Cardiopulmonary
Transplantation, Center for Cardiac
Support, Texas Heart Institute, St.
Luke\'s Episcopal Hospital, Houston,
Texas 77030, USA.
lschwenke@heart.thi.tmc.edu, "Current status of cardiac
transplantation and left ventricular
assist devices.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2010;37(3):319-21.
|
7968R
|
Frazier OH,, Tuzun E, Narin C, Cohn WE.
Cardiovascular Surgical Research
Laboratories, Texas Heart Institute,
St. Luke\\\'s Episcopal Hospital,
Houston, Texas 77030, USA.
lschwenke@heart.thi.tmc.edu, "Right ventricle-sparing left", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2010;37(3):276-9.
|
7967A
|
del Cañizo J, Rodríguez-Martínez D, Perez-
Caballero R, Quintana B, Ruiz-
Fernandez M.
Unidad de Medicina y Cirugia
Experimental, Hospital General
Universitario Gregorio Marañon,
Madrid, Spain. canizo@mce.hggm.es, "Low-cost pulsatile cardiac assist
device with compliant input
chamber.", Artif Organs. 2010 Feb;34(2):136-40. Epub 2009 Oct 10.
|
7964A
|
Schwarz KQ, Parikh SS, Chen X, Farrar DJ,
Steinmetz S, Ramamurthi S, Hallinan
W, Massey HT, Chen L.
University of Rochester Medical
Center, Rochester, New York 14642,
USA.
karl_schwarz@urmc.rochester.edu, "Non-invasive flow measurement of
a rotary pump ventricular assist
device using quantitative contrast
echocardiography.", J Am Soc Echocardiogr. 2010 Mar;23(3):324-9.
|
7938A
|
Schwarz KQ, Parikh SS, Chen X, Farrar DJ,
Steinmetz S, Ramamurthi S, Hallinan
W, Massey HT, Chen L.
University of Rochester Medical
Center, Rochester, New York 14642,
USA.
karl_schwarz@urmc.rochester.edu, "Non-invasive flow measurement of
a rotary pump ventricular assist
device using quantitative contrast
echocardiography.", J Am Soc Echocardiogr. 2010 Mar;23(3):324-9.
|
7938A
|
Tuzun E, Roberts K, Cohn WE, Sargin M,
Gemmato CJ, Radovancevic B,
Frazier OH.
Cardiovascular Surgical Research
Laboratories, Texas Heart Institute
at St. Luke\'s Episcopal Hospital,
Houston, Texas 77030, USA.
etuzun@heart.thi.tmc.edu, "In vivo evaluation of the HeartWare
centrifugal ventricular assist device.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2007;34(4):406-11.
|
7922A
|
Khalil HA, Kerr DT, Schusterman MA 2nd,
Cohn WE, Frazier OH, Radovancevic
B.
the Cardiovascular Surgical
Research Laboratories, Texas Heart
Institute at St. Luke\'s Episcopal
Hospital; The University of Texas
Medical School at Houston,
Houston, Texa, "Induced pulsation of a continuous-
flow total artificial heart in a mock
circulatory system.", J Heart Lung Transplant. 2010 2010 eb 13
|
7921A
|
Frazier OH,, Khalil HA, Benkowski RJ, Cohn WE.
Department of Cardiovascular
Surgery, Texas Heart Institute at St.
Luke\'s Episcopal Hospital, Houston., "Optimization of axial-pump
pressure sensitivity for a
continuous-flow total artificial
heart.", J Heart Lung Transplant 2010 Feb 3
|
7920A
|
Frazier OH,, Cohn WE, Tuzun E, Winkler JA,
Gregoric ID.
Cardiovascular Surgical Research
Laboratories, Texas Heart Institute
at St. Luke\'s Episcopal Hospital, Houston, Texas 77030, USA.
lschwenke@heart.thi.tmc.edu, "Continuous-flow total artificial
heart supports long-term survival
of a calf.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2009;36(6):568-74.
|
7919A
|
Pantalos GM, Ionan C, Koenig SC, Gillars KJ, Horrell T, Sahetya S, Colyer J, Gray LA Jr. From the Departments of Surgery and Biomedical Engineering, Cardiovascular Innovation Institute, University of Louisville, Louisville, Kentucky., "Expanded Pediatric Cardiovascular Simulator for Research and Training.", ASAIO J.2010 Jan-Feb; 56(1):67-72
|
7907A
|
Haines N, Wang S, Myers JL, Undar A.
Pediatric Cardiac Research
Laboratories, Department of
Pediatrics, Penn State Milton S.
Hershey Medical Center, Penn State
Hershey College of Medicine, Penn
State Hershey Children\'s Hospital,
Hershey, PA, USA., "Comparison of Two Types of
Neonatal Extracorporeal Life
Support Systems With Pulsatile and
Nonpulsatile Flow.", Artif Organs. 2009 2009 Oct 28.[Epub ahead of print]
|
7900A
|
Haines N, Wang S, Undar A, Alkan T, Akcevin
A. Pediatric Cardiac Research
Laboratories, Department of
Pediatrics, Milton S. Hershey Medical
Center, Hershey, Pennsylvania, USA., "Clinical outcomes of pulsatile and
non-pulsatile mode of perfusion.", J Extra Corpor Technol. 2009 Mar;41(1):P26-9.
|
7899A
|
Wang S, Haines N, Undar A. Pediatric Cardiac
Research Laboratories, Department
of Pediatrics, Milton S. Hershey
Medical Center and, Hershey,
Pennsylvania, USA., "Quantification of pressure-flow
waveforms and selection of
components for the pulsatile
extracorporeal circuit.", J Extra Corpor Technol. 2009 Mar;41(1):P20-5.
|
7898A
|
Wang S, Haines N, Richardson JS, Dasse KA,
Undar A. Pediatric Cardiac Research
Laboratories, Department of
Pediatrics, Penn State Milton S.
Hershey Medical Center, Penn State
College Medicine, Penn State
Children\'s Hospital, Hershey,
Pennsylvania 1, "Impact of the postpump resistance
on pressure-flow waveform and
hemodynamic energy level in a
neonatal pulsatile centrifugal pump.", ASAIO J. 2009 May-Jun;55(3):277-81.
|
7897A
|
Shu F, Vandenberghe S, Antaki JF.
Department of Biomedical
Engineering, Carnegie Mellon
University, Pittsburgh, PA 15219,
USA. fangjun@gmail.com, "The importance of dQ/dt on the Flow Field in a Turbodynamic Pump with Pulsatile Flow", Artif Organs. 2009 Sep;33(9):757-62
|
7862A
|
Sakota D, Sakamoto R, Yokoyama N,
Kobayashi M, Takatani S.
Department of Artificial Organs,
Tokyo Medical and Dental
University, Tokyo, Japan., "Glucose depletion enhances
sensitivity to shear stress-induced
mechanical damage in red blood
cells by rotary blood pumps.", Artif Organs. 2009 Sep;33(9):733-9.
|
7861A
|
Jahanmir S, Hunsberger AZ, Ren Z, Heshmat H,
Heshmat C, Tomaszewski MJ,
Walton JF.
MiTiHeart Corporation,
Gaithersburg, MD, USA, "Design of a small centrifugal blood
pump with magnetic bearings.", Artif Organs. 2009 Sep;33(9):714-26
|
7860A
|
Someya T,, Kobayashi M, Waguri S, Ushiyama T,
Nagaoka E, Hijikata W, Shinshi T,
Arai H, Takatani S.
Department of Cardiothoracic
Surgery, Graduate School of
Medicine Tokyo Medical, Tokyo,
Japan., "Development of a disposable
Maglev centrifugal blood pump
intended for one-month support
in bridge-to-bridge applications:
in vitro and initial in vivo
evaluation.", Artif Organs. 2009 Sep;33(9):704-13
|
7859A
|
Van Der Smissen B, Claessens T, Verdonck P, Van
Ransbeeck P, Segers P.
Department of Mechanics,
Biomechanics, University College
Ghent, Belgium.
Benjamin.VanDerSmissen@HoGent.b
e, "Design of an artificial left ventricular
muscle: an innovative way to actuate
blood pumps?", Artif Organs 2009 Jun;33(6):464-8.
|
7778A
|
Voitl P, Vollkron M, Bergmeister H,
Wieselthaler G, Schima H.
Center for Biomedical Engineering
and Physics, Medical University of
Vienna, Vienna, Austria., "Coronary hemodynamics and
myocardial oxygen consumption
during support with rotary blood
pumps.", Artif Organs. 2009 Jan;33(1):77-80
|
7735A
|
Slaughter MS, Bartoli CR, Sobieski MA, Pantalos
GM, Giridharan GA, Dowling RD,
Prabhu SD, Farrar DJ, Koenig SC.
Division of Cardiothoracic Surgery,
Cardiovascular Innovation Institute,
University of Louisville, Kentucky,
USA. Mark.Slaughter@louisville.edu, "Intraoperative evaluation of the HeartMate II flow estimator.", J Heart Lung Transplant 2009 Jan;28(1):39-43.
|
7727AH
|
Legendre D, Fonseca J, Andrade A, Biscegli JF,
Manrique R, Guerrino D, Prakasan
AK, Ortiz JP, Lucchi JC.
Institute Dante Pazzanese of
Cardiology, Escola Politécnica,
University of São Paulo, Brazil.
daniel.legendre@poli.usp.br, "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases.", Artif Organs. 2008 Jun;32(6):461-7.
|
7665A
|
Roszelle BN, Cooper BT, Long TC, Deutsch S,
Manning KB.
Department of Bioengineering, The
Pennsylvania State University,
University Park, Pennsylvania
16802, USA., "The 12 cc Penn State pulsatile pediatric ventricular assist device: flow field observations at a reduced beat rate with application to weaning.", ASAIO J. 2008 May-Jun;54(3):325-31.
|
7663A
|
|
|