Bench Tubing Studies

31 Matching Records
Laumen M, Kaufmann T, Timms D, Schlanstein P, Jansen S, Gregory S, Wong KC, Schmitz-Rode T, Steinseifer U. Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, German, "Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.", Artif Organs. 2010 Oct;34(10):798-806. doi: 10.1111/j.1525-1594.2010.01098.x.
8024A
Dur O, Lara M, Arnold D, Vandenberghe S, Keller BB, DeGroff C, Pekkan K. Biomedical Engineering Department, Carnegie Mellon University, Pittsburgh, PA 15219, USA., "Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios.", Artif Organs. 2009 Nov;33(11):967-76.
8008A
Frazier OH., Department of Cardiopulmonary Transplantation, Center for Cardiac Support, Texas Heart Institute, St. Luke\'s Episcopal Hospital, Houston, Texas 77030, USA. lschwenke@heart.thi.tmc.edu, "Current status of cardiac transplantation and left ventricular assist devices.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2010;37(3):319-21.
7968R
Frazier OH,, Tuzun E, Narin C, Cohn WE. Cardiovascular Surgical Research Laboratories, Texas Heart Institute, St. Luke\\\'s Episcopal Hospital, Houston, Texas 77030, USA. lschwenke@heart.thi.tmc.edu, "Right ventricle-sparing left", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2010;37(3):276-9.
7967A
del Cañizo J, Rodríguez-Martínez D, Perez- Caballero R, Quintana B, Ruiz- Fernandez M. Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Marañon, Madrid, Spain. canizo@mce.hggm.es, "Low-cost pulsatile cardiac assist device with compliant input chamber.", Artif Organs. 2010 Feb;34(2):136-40. Epub 2009 Oct 10.
7964A
Schwarz KQ, Parikh SS, Chen X, Farrar DJ, Steinmetz S, Ramamurthi S, Hallinan W, Massey HT, Chen L. University of Rochester Medical Center, Rochester, New York 14642, USA. karl_schwarz@urmc.rochester.edu, "Non-invasive flow measurement of a rotary pump ventricular assist device using quantitative contrast echocardiography.", J Am Soc Echocardiogr. 2010 Mar;23(3):324-9.
7938A
Schwarz KQ, Parikh SS, Chen X, Farrar DJ, Steinmetz S, Ramamurthi S, Hallinan W, Massey HT, Chen L. University of Rochester Medical Center, Rochester, New York 14642, USA. karl_schwarz@urmc.rochester.edu, "Non-invasive flow measurement of a rotary pump ventricular assist device using quantitative contrast echocardiography.", J Am Soc Echocardiogr. 2010 Mar;23(3):324-9.
7938A
Tuzun E, Roberts K, Cohn WE, Sargin M, Gemmato CJ, Radovancevic B, Frazier OH. Cardiovascular Surgical Research Laboratories, Texas Heart Institute at St. Luke\'s Episcopal Hospital, Houston, Texas 77030, USA. etuzun@heart.thi.tmc.edu, "In vivo evaluation of the HeartWare centrifugal ventricular assist device.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2007;34(4):406-11.
7922A
Khalil HA, Kerr DT, Schusterman MA 2nd, Cohn WE, Frazier OH, Radovancevic B. the Cardiovascular Surgical Research Laboratories, Texas Heart Institute at St. Luke\'s Episcopal Hospital; The University of Texas Medical School at Houston, Houston, Texa, "Induced pulsation of a continuous- flow total artificial heart in a mock circulatory system.", J Heart Lung Transplant. 2010 2010 eb 13
7921A
Frazier OH,, Khalil HA, Benkowski RJ, Cohn WE. Department of Cardiovascular Surgery, Texas Heart Institute at St. Luke\'s Episcopal Hospital, Houston., "Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart.", J Heart Lung Transplant 2010 Feb 3
7920A
Frazier OH,, Cohn WE, Tuzun E, Winkler JA, Gregoric ID. Cardiovascular Surgical Research Laboratories, Texas Heart Institute at St. Luke\'s Episcopal Hospital, Houston, Texas 77030, USA. lschwenke@heart.thi.tmc.edu, "Continuous-flow total artificial heart supports long-term survival of a calf.", Tex Heart Inst J. Tex Heart Inst J. 2009; 36(2): 186. 2009;36(6):568-74.
7919A
Pantalos GM, Ionan C, Koenig SC, Gillars KJ, Horrell T, Sahetya S, Colyer J, Gray LA Jr. From the Departments of Surgery and Biomedical Engineering, Cardiovascular Innovation Institute, University of Louisville, Louisville, Kentucky., "Expanded Pediatric Cardiovascular Simulator for Research and Training.", ASAIO J.2010 Jan-Feb; 56(1):67-72
7907A
Haines N, Wang S, Myers JL, Undar A. Pediatric Cardiac Research Laboratories, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children\'s Hospital, Hershey, PA, USA., "Comparison of Two Types of Neonatal Extracorporeal Life Support Systems With Pulsatile and Nonpulsatile Flow.", Artif Organs. 2009 2009 Oct 28.[Epub ahead of print]
7900A
Haines N, Wang S, Undar A, Alkan T, Akcevin A. Pediatric Cardiac Research Laboratories, Department of Pediatrics, Milton S. Hershey Medical Center, Hershey, Pennsylvania, USA., "Clinical outcomes of pulsatile and non-pulsatile mode of perfusion.", J Extra Corpor Technol. 2009 Mar;41(1):P26-9.
7899A
Wang S, Haines N, Undar A. Pediatric Cardiac Research Laboratories, Department of Pediatrics, Milton S. Hershey Medical Center and, Hershey, Pennsylvania, USA., "Quantification of pressure-flow waveforms and selection of components for the pulsatile extracorporeal circuit.", J Extra Corpor Technol. 2009 Mar;41(1):P20-5.
7898A
Wang S, Haines N, Richardson JS, Dasse KA, Undar A. Pediatric Cardiac Research Laboratories, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State College Medicine, Penn State Children\'s Hospital, Hershey, Pennsylvania 1, "Impact of the postpump resistance on pressure-flow waveform and hemodynamic energy level in a neonatal pulsatile centrifugal pump.", ASAIO J. 2009 May-Jun;55(3):277-81.
7897A
Shu F, Vandenberghe S, Antaki JF. Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA 15219, USA. fangjun@gmail.com, "The importance of dQ/dt on the Flow Field in a Turbodynamic Pump with Pulsatile Flow", Artif Organs. 2009 Sep;33(9):757-62
7862A
Sakota D, Sakamoto R, Yokoyama N, Kobayashi M, Takatani S. Department of Artificial Organs, Tokyo Medical and Dental University, Tokyo, Japan., "Glucose depletion enhances sensitivity to shear stress-induced mechanical damage in red blood cells by rotary blood pumps.", Artif Organs. 2009 Sep;33(9):733-9.
7861A
Jahanmir S, Hunsberger AZ, Ren Z, Heshmat H, Heshmat C, Tomaszewski MJ, Walton JF. MiTiHeart Corporation, Gaithersburg, MD, USA, "Design of a small centrifugal blood pump with magnetic bearings.", Artif Organs. 2009 Sep;33(9):714-26
7860A
Someya T,, Kobayashi M, Waguri S, Ushiyama T, Nagaoka E, Hijikata W, Shinshi T, Arai H, Takatani S. Department of Cardiothoracic Surgery, Graduate School of Medicine Tokyo Medical, Tokyo, Japan., "Development of a disposable Maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.", Artif Organs. 2009 Sep;33(9):704-13
7859A
Van Der Smissen B, Claessens T, Verdonck P, Van Ransbeeck P, Segers P. Department of Mechanics, Biomechanics, University College Ghent, Belgium. Benjamin.VanDerSmissen@HoGent.b e, "Design of an artificial left ventricular muscle: an innovative way to actuate blood pumps?", Artif Organs 2009 Jun;33(6):464-8.
7778A
Voitl P, Vollkron M, Bergmeister H, Wieselthaler G, Schima H. Center for Biomedical Engineering and Physics, Medical University of Vienna, Vienna, Austria., "Coronary hemodynamics and myocardial oxygen consumption during support with rotary blood pumps.", Artif Organs. 2009 Jan;33(1):77-80
7735A
Slaughter MS, Bartoli CR, Sobieski MA, Pantalos GM, Giridharan GA, Dowling RD, Prabhu SD, Farrar DJ, Koenig SC. Division of Cardiothoracic Surgery, Cardiovascular Innovation Institute, University of Louisville, Kentucky, USA. Mark.Slaughter@louisville.edu, "Intraoperative evaluation of the HeartMate II flow estimator.", J Heart Lung Transplant 2009 Jan;28(1):39-43.
7727AH
Legendre D, Fonseca J, Andrade A, Biscegli JF, Manrique R, Guerrino D, Prakasan AK, Ortiz JP, Lucchi JC. Institute Dante Pazzanese of Cardiology, Escola Politécnica, University of São Paulo, Brazil. daniel.legendre@poli.usp.br, "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases.", Artif Organs. 2008 Jun;32(6):461-7.
7665A
Roszelle BN, Cooper BT, Long TC, Deutsch S, Manning KB. Department of Bioengineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA., "The 12 cc Penn State pulsatile pediatric ventricular assist device: flow field observations at a reduced beat rate with application to weaning.", ASAIO J. 2008 May-Jun;54(3):325-31.
7663A