FLOWMATTERS™ NEWSLETTERS
Get the latest information on a variety of applications, case reports, studies, and trials. Subscribe Here >>

 

 

Large Animal Cardiovascular

Quantitative blood flow data in the conscious animal is a powerful tool for the study hemodynamic physiology. Researchers studying the physiology of various conditions which alter systemic blood flow and distribution such as exercise, aging, heart failure, and circulatory compromise measure blood flow in conscious animal models.

 

Applications include:

 

Real-Time Cardiac Output

Ascending Aorta & Pulmonary Artery Flowprobes Acute & Chronic Research Models

 

Coronary Artery Blood Flow Measurement

Continuous, high resolution volume flow measurement for acute/chronic research models


Exercise Physiology

Treadmill studies have been performed in large animal models such as sheep, calves, pigs and dogs where they have been trained to walk or run on a treadmill much like people exercising or in a medical examination stress test. Experts rely on Transonic Systems’ implantable flowprobes for such important measurements as cardiac output, hind limb blood flow, carotid and renal arterial flows to understand the underlying mechanisms of pressor response, peripheral vasoconstriction, and muscle metaboreflex under the stress of mild to moderate exercise.

 

Multiple flowprobes may be implanted on the ascending aorta and peripheral vessels. The leads are exteriorized with a skin button or small connector for tether attachment during recordings. Leads are protected by spring sheaths or other deterrents. Animals, trained on the treadmill, are accustomed to this routine monitoring. Transonic ultrasonic flowprobes are compatible with telemetric pressure recording devices such as Transoma/DSI® and ultrasonic sonomicrometry for measuring ventricular contractility by Sonometrics, Inc.®

 

The following studies report the use of integrated instrumentation with four flowprobes implanted in each subject:

 

Flowprobe Suggestions & Application Support (Dog Model)

Vessel
& Body Weight
Acute
Flowprobe &
Configuration
Chronic
Flowprobe &
Configuration
References
aorta ascending
8-12 kg
MA14PAU, MA16PAU
14, 16mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC14PAU, MC16PAU
14, 16mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
aorta ascending
12-15kg
MA14PAU, MA16PAU
14, 16mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC14PAU, MC16PAU
14, 16mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
aorta ascending
18-22kg
MA16PAU, MA20PAU
16, 20mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC20PAU
20mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
aorta ascending
22-25kg
MA20PAU, MA24PAU
20, 24mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC20PAU, MC24PAU
20, 24mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
aorta ascending
25-30kg
MA24PAU, MA28PAU
20, 24mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC24PAU, MC28PAU
24, 28mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
bronchial artery
12-28kg
MA1PRB
1mm Precision R-Series, Back Cable Exit

CRA10 Connector with 60cm Cable
MC1PRB
1mm Precision R-Series, Back Cable Exit
~50-65cm Cable

CM4B, CB12, CS12, CRS10
 
common carotid artery MA4PSB
4mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC4PSS
4mm Precision S-Series, Side Cable Exit
~50-65cm Cable

CM4B, CB12, CS12, CRS10
 
internal carotid artery MA2.5PSB
2.5mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2.5PSS
2.5mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable

 
left anterior descending coronary artery
Dog 8-15kg
MA1.5PRB
1.5mm Precision R-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC1.5PRS
1.5mm Precision R-Series, Side Cable Exit
Silicone Flange

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Blood Flow Measurement in Canine Left Anterior Descending (LAD) Coronary Artery
left anterior descending coronary artery
Dog 16-20kg
MA2PSB
2mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2PSS
2mm Precision S-Series, Side Cable Exit
Silicone Flange

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Blood Flow Measurement in Canine Left Anterior Descending (LAD) Coronary Artery
left anterior descending coronary artery
Dog >20kg
MA2.5PSB
2.5mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2.5PSS
2.5mm Precision S-Series, Side Cable Exit
Silicone Flange

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Blood Flow Measurement in Canine Left Anterior Descending (LAD) Coronary Artery
left coronary artery circumflex (LCx)
>20kg
MA3PSB
3mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC3PSS
3mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
left coronary artery circumflex (LCx)
>16-20kg
MA2.5PSB
2.5mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2.5PSS
2.5mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
femoral artery
MA3PSB, MA4PSB
3, 4mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC3PSS, MC4PSS
3, 4mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
hepatic artery
25kg
MA3PSS, MA4PSS
3, 4mm Precision S-Series, Side Cable Exit

CRA10 Connector with 100cm Cable
MC3PSS, MC4PSS
3, 4mm Precision S-Series, Side Cable Exit
silicone wrap

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Chronic Hepatic & Portal Blood Flow Measurement in Dog 
intercostal artery
MA2PSB
2mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2PSB
2mm Precision S-Series, Back Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
intestinal serosa and mucosa
Type S (straight) Laser Doppler Flowprobes    
jugular vein
10kg
MA4PSB
4mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
   
internal mammary artery (thoracic)
MA3PSB
3mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC3PSB
3mm Precision S-Series, Back Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
cranial pancrea- ticoduodenal vein
10-20kg
MA4PSB
4mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC4PSS
4mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Chronic Blood Flow Measurement in the Canine Pancreaticoduodenal Vein 
pancreas perfusion
13-18 kg
Type R (right angle) Laser Doppler Flowprobes    
portal vein
10-25kg
MA8PAU, MA10PAU
8, 10mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC8PAU, MC10PAU
8, 10mm
COnfidence®
Flowprobes
or MC8PSS, MC10PSS Precision S-Series

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Chronic Hepatic & Portal Blood Flow Measurement in Dog 
pulmonary artery
8-12kg
MA14PAU, MA16PAU
14, 16mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC14PAU, MC16PAU
14, 16mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
pulmonary artery
18-22kg
MA16PAU, MA20PAU
16, 20mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC16PAU, MC20PAU
16, 20mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
pulmonary artery
22-25kg
MA20PAU, MA24PAU
20, 24mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC20PAU, MC24PAU
20, 24mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
pulmonary artery
25-30kg
MA24PAU, MA28PAU
24, 28mm
COnfidence®
Flowprobes

CRA10 Connector with 200cm Cable
MC24PAU, MC28PAU
24, 28mm
COnfidence®
Flowprobes

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
pulmonary vein
MA6PSB
6mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC6PSB
6mm Precision S-Series, Back Cable Exit

CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
renal artery
MA2.5PSS, MA3PSS
2.5, 3mm Precision S-Series, Side Cable Exit

CRA10 Connector with 100cm Cable
MC3PSS, MC4PSS
3, 4mm Precision S-Series, Side Cable Exit
silicone wrap

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
Chronic Renal Blood Flow Measurement in Dog 
subpleural micro-circulation
16-19 kg
Type N (11 gauge) Laser Doppler Flowprobes    
thoracodorsal artery
MA2.5PSB
2.5mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC2.5PSS
2.5mm Precision S-Series, Side Cable Exit

CM4B, CB12, CS12, CRS10 Connectors with a ~50-65cm Cable
 
vena cava inferior
MA10PSB, MA12PSB
10, 12mm Precision S-Series, Back Cable Exit

CRA10 Connector with 100cm Cable
MC10PSS, MC12PSS
10, 12mm Precision S-Series, Side Cable Exit
wide silicone reflector