 HT110 Bypass Flowmeter & HXLSensor
|
Designed for ease of use in the critical care setting, the HT110 Bypass Flowmeter and Sterile
Tubing Flowsensor monitor volume flow through medical tubing in intensive care and outside the surgical field in the operating room. Clamp-on
sterile tubing sensors do not compromise tubing sterility or non-thrombogenic surfaces.
By providing reliable, immediate volume flow
measurements, the Bypass Flowmeter system enhances safety for the patient by insuring accurate delivery in procedures using roller pumps, centrifugal pumps and
pressuredriven circuits.
|
|
Transonic XL Sensors Ultrasonic transit-time sensors, specifically designed for tubing,
measure volume flow with highest accuracy. Most non-aerated liquids can be measured including saline and buffer solutions,
blood, water and even diesel fuel. No physical contact is made with the fluid media.
XL-Series Flowsensors can be calibrated and programmed for up to 4 different fluid
/ temperature / tubing combinations and will work with most flexible tubing types. Sensor size is determined by outside diameter of the tubing.
|
|
Weight/Size
HT110: single channel 7 lbs. (3.2 Kg), 8 1/2" w x 3 1/2" h x 13" d HT110: 90-265 Volts; 50-60Hz, single phase, 40 Watts, (1.5 Amp fuse)
Electrical Isolation: Flowmeter complies with USA standards for medical and dental equipment (UL544), and with European standards for medical and ultrasonic apparatus
(DIN IEC 601-1, VDE 0750 -1/5.82, IEC 62D Sec. 31). Alpha-Numeric Display:
Single row by 16 character liquid crystal that displays error conditions, calibration and probe parameters. Flowmeter Display:
0.1 ml/min to 200l/min (typical), displayed by a 4 1/2 digit, 7 segment LED. Flow Monitor Outputs: Analog mean and pulsatile flow Probe Connector:
15 pin, high density D-Sub connector Digital Identification: Probe identification & calibration parameters programmed into flowprobe connector
Ultrasonic Frequency: 300 KHz to 7.2 MHz Accepts: XL-Series sterile tubing flowsensors for extracorporeal tubing
Electrical Specifications
Power AC Input:
90 - 265 VAC; 50 - 60 Hz, 40 watts; Fuses: Two, 1.5A / 250V, 5 x 20 mm Connector: International 3 conductor type IEC 320 Flow Monitor Average:
Grounded BNC fitting ± 5.0 volts peak, Output impedance 500 ¥; Filtered at .1Hz. Pulsatile: Grounded BNC fitting ± 5.0 volts peak, Output impedance 500 ¥; Filtered
at 5Hz Bubble Switch Isolated ground BNC fitting connected to SPST solid state relay, optically coupled, normally closed
Voltage Isolation: 1000 Vdc Max switch voltage: 40 Vdc
Max switch current: 0.5 Amps continuous Max switch power: 0.35 watts Typ. ON resistance: 1 ohm RS-232:
9-pin D-Sub connector, standard RS232 parameters Isolated ground: pin 5; Transmit: pin 2; Received: pin 3
Computer Option
The (-P) Personal Computer Interface Option allows the user to interface
the flowmeter to a standard IBM-PC computer to display, record and playback flow waveforms and data.
Package includes: Additional circuitry within the flowmeter cabinet;
- a standard RS-232 cable
- WinDaq - PC compatible software to display &
record flow data.
|