Transonic Systems Inc.
top_right

Publications | Site Map

 
 
Research Surgery Critical Care Hemodialysis Radiology OEM About Contact FAQ's
 

 

 

 

 

 

H-XL Sterile Tubing Flowsensors

 

for the HT110(R) Bypass Flowmeter

XL_Large
The New Generation Flowsensor for All Tubing Applications with Unsurpassed Accuracy and Flow Resolution Over a Wide Dynamic Range

Unique ultrasonic transit time technology measures volume flow with H-XL Sterile Tubing Flowsensors specifically designed for accuracy on sterile medical tubing.

Transonic H-XL sensors clip on to the outside of flexible tubing to measure most non-aerated liquids including saline and buffer solutions, blood and water. The reusuable clip-on sensor has no contact with liquid, thereby preserving the thrombogenicity and sterility of the fluid. Bidirectional volume flow is displayed in mL or L/min. The H-XL sensor can be calibrated for different fluids and temperatures and customized for specialized applications. Sensor size is determined by outside diameter of the tubing.

Accurate

  • Uses “X” ultrasound illumination to ensure precision measurements
  • Stable low zero offset & increased accuracy under conditions ofperturbed flow
  • Excellent frequency response for pulsatile flow analysis

Convenient

  • No contact with liquid; avoids cross contamination
  • Measures most non-aerated solutions
  • Molded clamp-on design for easy care & handling
  • Fabricated and custom-calibrated for a wide range of tubing sizes and materials 1/8” - 1 1/4” OD (3.1 -19.5 mm)

Catalog Numbers

Tubing Sensor

Tubing Specifications

Typical Applications

Tubing ID

Wall Thickness

Tubing OD

Catalog #

inches

mm

inches

mm

inches

mm

H2XL

In sizes 2XL-5XL ratio of tubing wall thickness to OD must not exceed 1:5 for PVC; 1:3 for silicone

1/8 - 5/32

3.1 - 4.0

Carotid Shunts, Research

H3XL

3/16 - 7/32

4.7 - 5.5

H4XL

1/4 - 9/32

6.3 - 7.7

H5XL

5/16 - 11/32

7.8 - 8.7

H6XL

1/4

6.4

1/16

1.6

3/8

9.5

Pediatric
CP Bypass
ECMO

H7XL

1/4

6.4

3/32

2.4

7/16

11.1

H8XL

3/8

9.5

1/16

1.6

1/2

12.7

H9XL

3/8

9.5

3/32

2.4

9/16

14.3

Adult CP Bypass

H10XL

1/2

12.7

1/16

1.6

5/8

15.9

H11XL

1/2

12.7

3/32

2.4

11/16

17.5

H12XL

1/2

12.7

1/8

3.2

3/4

19.0

Laboratory Settings

H14XL

5/8

15.9

1/8

3.2

7/8

22.2

H16XL

3/4

19.0

1/8

3.2

1

25.4

H20XL

1

25.4

1/8

3.2

1 1/4

31.8

Neurosurgery

Tubing

Catalog  #

OD
(inches)

SENSOR

1/8 - 3/16

HQN 2XL for Pruitt-Inhara Shunt (2mm)

3/16 - 1/4

HQN 3XL for Javid Shunt (3mm)

Sensor

Tubing

Stock Tubing

ID

 

WALL

H2XL

3/32

x

1/32

Tygon S-50-HL

H3XL

1/8

x

1/32

No stock tubing

H4XL

-x-

No Stock Tubing

H5XL

-x-

No Stock Tubing

H6XL

1/4

x

1/16

MEDIFLEX, Tygon S-50-HL

H7XL

1/4

x

3/32

MEDIFLEX, Tygon S-50-HL

H8XL

3/8

x

1/16

Tygon S-50-HL

H9XL

3/8

x

3/32

BENTLY BYPASS 70, MEDIFLEX, Tygon S-50-HL

H10XL

1/2

x

1/16

Tygon S-50-HL

H11XL

1/2

x

3/32

BENTLY BYPASS 70, Tygon S-50-HL

H12XL

1/2

x

1/8

Tygon S-50-HL

H14XL

5/8

x

1/8

No stock tubing

H16XL

3/4

x

1/8

No stock tubing

H20XL

1

x

1/8

No stock tubing

 

 

 

 
Start receiving our
Flow Matters™ Newsletter.









 

 

 

 

 

 

Blue_Printer90

Print Page

Catalog90

View Catalog

 

 

 

 

 Surgery | Critical Care | Research | Hemodialysis | OEM | Publications | Customer Service

 

 