 The New Generation Flowsensor for All
Tubing Applications with Unsurpassed Accuracy and Flow Resolution Over a Wide Dynamic Range
Unique ultrasonic transit time technology
measures volume flow with H-XL Sterile Tubing Flowsensors specifically designed for accuracy on sterile medical tubing.
Transonic H-XL sensors clip on to the
outside of flexible tubing to measure most non-aerated liquids including saline and buffer solutions, blood and water. The reusuable clip-on sensor has no contact
with liquid, thereby preserving the thrombogenicity and sterility of the fluid. Bidirectional volume flow is displayed in mL or L/min. The H-XL sensor can be
calibrated for different fluids and temperatures and customized for specialized applications. Sensor size is determined by outside diameter of the tubing.
Accurate
- Uses “X” ultrasound illumination to ensure precision measurements
- Stable low zero offset & increased accuracy under conditions ofperturbed
flow
- Excellent frequency response for pulsatile flow analysis
Convenient
- No contact with liquid; avoids cross contamination
- Measures most non-aerated solutions
- Molded clamp-on design for easy care & handling
- Fabricated and custom-calibrated for a wide range of tubing sizes and
materials 1/8” - 1 1/4” OD (3.1 -19.5 mm)
Catalog Numbers
|
Tubing Sensor
|
Tubing Specifications
|
Typical Applications
|
|
Tubing ID
|
Wall Thickness
|
Tubing OD
|
|
Catalog #
|
inches
|
mm
|
inches
|
mm
|
inches
|
mm
|
|
H2XL
|
In sizes 2XL-5XL ratio of tubing wall thickness to OD must not exceed 1:5 for PVC; 1:3 for silicone
|
1/8 - 5/32
|
3.1 - 4.0
|
Carotid Shunts, Research
|
|
H3XL
|
3/16 - 7/32
|
4.7 - 5.5
|
|
H4XL
|
1/4 - 9/32
|
6.3 - 7.7
|
|
H5XL
|
5/16 - 11/32
|
7.8 - 8.7
|
|
H6XL
|
1/4
|
6.4
|
1/16
|
1.6
|
3/8
|
9.5
|
Pediatric CP Bypass ECMO
|
|
H7XL
|
1/4
|
6.4
|
3/32
|
2.4
|
7/16
|
11.1
|
|
H8XL
|
3/8
|
9.5
|
1/16
|
1.6
|
1/2
|
12.7
|
|
H9XL
|
3/8
|
9.5
|
3/32
|
2.4
|
9/16
|
14.3
|
Adult CP Bypass
|
|
H10XL
|
1/2
|
12.7
|
1/16
|
1.6
|
5/8
|
15.9
|
|
H11XL
|
1/2
|
12.7
|
3/32
|
2.4
|
11/16
|
17.5
|
|
H12XL
|
1/2
|
12.7
|
1/8
|
3.2
|
3/4
|
19.0
|
Laboratory Settings
|
|
H14XL
|
5/8
|
15.9
|
1/8
|
3.2
|
7/8
|
22.2
|
|
H16XL
|
3/4
|
19.0
|
1/8
|
3.2
|
1
|
25.4
|
|
H20XL
|
1
|
25.4
|
1/8
|
3.2
|
1 1/4
|
31.8
|
|
Neurosurgery
|
|
Tubing
|
Catalog #
|
|
OD (inches)
|
SENSOR
|
|
1/8 - 3/16
|
HQN 2XL for Pruitt-Inhara Shunt
(2mm)
|
|
3/16 - 1/4
|
HQN 3XL for Javid Shunt (3mm)
|
|
Sensor
|
Tubing
|
Stock Tubing
|
|
ID
|
|
WALL
|
|
H2XL
|
3/32
|
x
|
1/32
|
Tygon S-50-HL
|
|
H3XL
|
1/8
|
x
|
1/32
|
No stock tubing
|
|
H4XL
|
-x-
|
No Stock Tubing
|
|
H5XL
|
-x-
|
No Stock Tubing
|
|
H6XL
|
1/4
|
x
|
1/16
|
MEDIFLEX, Tygon S-50-HL
|
|
H7XL
|
1/4
|
x
|
3/32
|
MEDIFLEX, Tygon S-50-HL
|
|
H8XL
|
3/8
|
x
|
1/16
|
Tygon S-50-HL
|
|
H9XL
|
3/8
|
x
|
3/32
|
BENTLY BYPASS 70, MEDIFLEX, Tygon S-50-HL
|
|
H10XL
|
1/2
|
x
|
1/16
|
Tygon S-50-HL
|
|
H11XL
|
1/2
|
x
|
3/32
|
BENTLY BYPASS 70, Tygon S-50-HL
|
|
H12XL
|
1/2
|
x
|
1/8
|
Tygon S-50-HL
|
|
H14XL
|
5/8
|
x
|
1/8
|
No stock tubing
|
|
H16XL
|
3/4
|
x
|
1/8
|
No stock tubing
|
|
H20XL
|
1
|
x
|
1/8
|