Transonic Systems Inc.
top_right

Publications | Site Map

 
 
Research Surgery Critical Care Hemodialysis Radiology OEM About Contact FAQ's
 

 

 

 

 

 

TS420 Perivascular Flow Modules

Unprecedented Volume Flow Capability with Precision Perivascular Probes

 

420
TS420 Perivascular Flowmeter Module

Transonic Systems' hallmark simple plug & play TS420 Flow Modules offer an unmatched range of precision flowprobes for vessels 0.25 mm and larger; a spectrum of applications including cardiac output and cardiovascular dynamics, renal hypertension, carotid thrombosis and stroke models, hemorrhagic shock, ischemia/reperfusion, portal hypertension, and hindlimb studies.

  • Accurately measures volume flow of less than 1 ml/min
  • Expanded ultrasonic frequency range for the smallest flowprobes imaginable! Implantable 0.5 mm and 0.7 mm mouse probes.
  • 160 Hz bandwidth to accurately characterize flow dynamics at high mouse heart rates
  • Analog meter displays voltage proportional to flow
  • Easy access front panel receptable for chronic probe calibration keys
     
Matching Flowprobes


Precision Perivascular Flowprobes (PDF)

  • Volume Flow Data from Mice to Men
  • Acute Use (MA) and Implantable (MC) Flowprobes
  • for arteries, veins and ducts
  • Multiple Configurations
  • to meet experimental needs of many animal models
  • Gold Standard Accuracy:
  • Validated ultrasonic transit-time technology: Waveforms demonstrate Transonic's signature zero baseline stability and high resolution of flows less than 1 ml/min..
     

PS Series Nanoprobes

  • nano0.5 - 0.7 mm Micro-flowprobes for murine studies with the TS420 flow module.
  • MA-acute use probes supplied with handle. The smallest probes  imaginable! Easily stabilize probe position under the microscope with a micromanipulator for experiments in anesthetized mice and rats. Mc-custom implantable flowprobes for conscious mouse studies.
     

Rat / Rodent Probes
Flowprobes specifications for rat and rodent studies

Micro-probes for Mouse CO
Micro-flowprobes for chronic cardiac output in mice.
 

4sb
4PSB

PS & PR Series for any vessel

  • 1-20 mm
  • MA-Standard Acute Use Probe.
  • MC-Custom Implantable Configuration
     

PMP_Handle_Probe3PMP - Series Handle Flowprobes

  • 2-14 mm
  • For intraoperative measurements in preclinical animal trials where devices that match those used in clinical surgical settings are preferred.

A_probe-newPAX Series Precision Cardiac Output Flowprobes

  • 8-36 mm
  • Accurate volume flow measurements for ascending aorta and pulmonary artery with nonlaminar or turbulent flow profiles.

VpathV-Series Microcirculation Probes for Acute Use Only

  • 0.5 - 0.7 mm
  • Transonic System' original probe series for small vessels < 0.7 mm. Mirrored ultrasonic illumination; robust design. Flowprobnes come with stabilizing handle and require more acoustic coupling than Nanoprobes.

Connectors >

Accessories >

Ordering Key >

 

PowerLab®  Data Acquisition Systems

ML870_STransonic TS420 Flowmeter modules provide analog output signals for their measured parameters. PowerLab provides A/D converter and software systems to display, analyze, and store data.

 

 

 
Start receiving our
Flow Matters™ Newsletter.









 

 

 

 

 

 

 

Blue_Printer90

Print Page

 

 

 

 

 

 

 Surgery | Critical Care | Research | Hemodialysis | OEM | Publications | Customer Service

 

 

 ©2007 Transonic Systems Inc.  All rights Reserved. Privacy Statement